1.5 Performance parameter
Index name | Index requirement | Remarks |
Range of measured angular rate
(°/s) |
±400 | |
Scale Factor Non-Linearity at
fixed temperature (ppm) |
≤20 | |
Asymmetry of Scaling Factor at
Room Temperature (ppm) |
≤20 | |
Scale Factor Repeatability at
fixed temperature (ppm) |
≤20 | |
Scale Factor Repeatability at
full temperature range from -40℃ till 60℃ (ppm) |
≤50 | |
Bias Drift at fixed temperature
(10s,1σ,°/h) |
≤0.02 | |
Bias Drift Repeatability at
fixed temperature (1σ,°/h) |
≤0.01 | |
Bias Drift Repeatability at full temperature
range from -40℃ till 60℃ (1σ,°/h) |
≤0.05 | Fixed-point constant
temperature test |
Bias Drift at fulltemperature
range from -40℃ till 60℃ (100s,1σ,°/h) |
≤0.04 | Off line compensation |
Random Walk
(°/√h) |
≤0.003 | |
Warm up time
(min) |
0 | |
Random vibration
(°/h) |
5.3 | |
Shock
(°/h) |
≤0.1 | Zero deviation before
and after impact |
Resolving power | ≤0.5 | |
Zero deviation change
before and after vibration (°/h) |
≤0.10 | |
Zero bias sensitivity
(°/h/GS) |
≤0.10 | |
Storagge temperature | -55℃~70℃ | |
Operating temperature | -40℃~70℃ |
Reviews